| Excitation: | 
Low Flow Cutoff: | 
| DC pulsed | 
0 ~ 9.9 % | 
| Display: | 
Self Diagnosis: | 
| 3 lines of LCD | 
The following error message | 
| Page 1/ Line 1 | 
 are displayed if failure occurs | 
| 5-digit flowrate | 
- Coil failure | 
| Page 1/ Line 2 | 
- Power failure | 
| 11-digit forward totalizer | 
- Overranged output | 
| Page 1/ Line 3 | 
- Internal error | 
| Battery status, flow velocity | 
- Overflow | 
| Page 2/ Line 1 | 
- Empty pipe | 
| 11-digit totalizer | 
Cable Entry: | 
| Page 2/ Line 2 | 
Standard :PG11  Option:1/2"NPTF | 
| 11-digit reverse totalizer | 
Protection Class: | 
| Page 2/ Line 3 | 
IP 67 | 
| Display instantaneous velocity | 
IP 68 (Submersible) | 
| Page 3 | 
Explosion Proof, Exd(ib)ibqIIBT5 | 
| Alarm | 
Ambient Temp.: | 
| Flow Unit: | 
 | 
| M3/Hr, M3/min, M3/sec, L/Hr, L/min | 
Housing Material: | 
| GPH, GPM, GPS, ML/H, ML/m, ML/S | 
Aluminum alloy | 
| Totalizer Unit: | 
Power Supply: | 
| M3, Gallon, Liter, ML | 
3.6V battery supply | 
| Measuring Range: | 
Battery Life: | 
| Min.  0 ~ 0.15 m/s | 
2~3 years | 
| Max. 0 ~ 15.0 m/s | 
Determined by size & function | 
| Accuracy: | 
Communication Protocol: | 
| +/-0.3% of reading (Velocity >=0.5 m/s) | 
RS 485 (MODBUS protocol) | 
| +/-0.0015 m/s (Velocity£¼0.5 m/s) | 
Weight: | 
| Repeatability: | 
2.0 Kg (Compact) | 
| +/-0.05% of reading | 
4.3 Kg (Separate) | 
| Pulse Output: | 
Mounting: | 
| Open collector | 
Wall mounting | 
| Load | 
Bracket on 2" pipe | 
| 3 ~ 30 Vdc, max. 20 mA | 
Compact version ( Installed on sensor) | 
| Pulse Rate: | 
  | 
| 1)Scaled pulse ( Liter/Pulse, other) | 
  | 
| 2)Frequency: 1~5000 Hz | 
  | 
| Keys: | 
  | 
| 4 control keys to change parameters | 
  | 
| and switch display interface | 
  | 
| Damping: | 
  | 
| 0.1~99.9s | 
  | 
| Data Storage: | 
  | 
| Operation parameters and totalizer are  | 
  | 
stored by EEPROM for more than 10 years
 
  |