Excitation: |
Low Flow Cutoff: |
DC pulsed |
0 ~ 9.9 % |
Display: |
Self Diagnosis: |
3 lines of LCD |
The following error message |
Page 1/ Line 1 |
are displayed if failure occurs |
5-digit flowrate |
- Coil failure |
Page 1/ Line 2 |
- Power failure |
11-digit forward totalizer |
- Overranged output |
Page 1/ Line 3 |
- Internal error |
Battery status, flow velocity |
- Overflow |
Page 2/ Line 1 |
- Empty pipe |
11-digit totalizer |
Cable Entry: |
Page 2/ Line 2 |
Standard :PG11 Option:1/2"NPTF |
11-digit reverse totalizer |
Protection Class: |
Page 2/ Line 3 |
IP 67 |
Display instantaneous velocity |
IP 68 (Submersible) |
Page 3 |
Explosion Proof, Exd(ib)ibqIIBT5 |
Alarm |
Ambient Temp.: |
Flow Unit: |
|
M3/Hr, M3/min, M3/sec, L/Hr, L/min |
Housing Material: |
GPH, GPM, GPS, ML/H, ML/m, ML/S |
Aluminum alloy |
Totalizer Unit: |
Power Supply: |
M3, Gallon, Liter, ML |
3.6V battery supply |
Measuring Range: |
Battery Life: |
Min. 0 ~ 0.15 m/s |
2~3 years |
Max. 0 ~ 15.0 m/s |
Determined by size & function |
Accuracy: |
Communication Protocol: |
+/-0.3% of reading (Velocity >=0.5 m/s) |
RS 485 (MODBUS protocol) |
+/-0.0015 m/s (Velocity£¼0.5 m/s) |
Weight: |
Repeatability: |
2.0 Kg (Compact) |
+/-0.05% of reading |
4.3 Kg (Separate) |
Pulse Output: |
Mounting: |
Open collector |
Wall mounting |
Load |
Bracket on 2" pipe |
3 ~ 30 Vdc, max. 20 mA |
Compact version ( Installed on sensor) |
Pulse Rate: |
|
1)Scaled pulse ( Liter/Pulse, other) |
|
2)Frequency: 1~5000 Hz |
|
Keys: |
|
4 control keys to change parameters |
|
and switch display interface |
|
Damping: |
|
0.1~99.9s |
|
Data Storage: |
|
Operation parameters and totalizer are |
|
stored by EEPROM for more than 10 years
|