Đồng hồ đo lưu lượng chất lỏng bằng phương pháp siêu âm
Tokyo Keiki JAPAN
No Pressure Loss (pump power savings)
No Wetted Parts (no contact with liquid)
No Moving Parts (no wear)
No Need to Stop the Process (easy installation)
Water Distribution
Factory Utilities
HVAC Systems
Process Monitoring
Replacement for old in-line meters
Desalination Processes
Measuring Accuracy : +/- 1.0~2.5% of reading
4-20mA Output (1ch)
Contact Output (1ch)
Data Logging (1min. intervals; up to 1month)
RS-485 Modbus Output (1ch) (Option)
Analog Current Input (1ch) (Option)
Smaller, Compact Footprint & Size*1
Lower Power Consumption *2
RoHS Compliant
Specifications
Đồng hồ đo lưu lượng chất lỏng bằng phương pháp siêu âm
Measurement | Method | Ultrasonic pulse transit time difference method | ||
---|---|---|---|---|
Diameter Range | DN 25mm - 600mm | |||
Accuracy | Pipe Diameter | Velocity ≧ 1m/s | Velocity < 1m/s | |
DN 25mm - 40mm (*1) | ±2.5% R.D. | ±0.025m/s | ||
DN 50mm - 90mm | ±2.0% R.D. | ±0.020m/s | ||
DN 100mm - 250mm | ±1.5% R.D. | ±0.015m/s | ||
DN 300mm - 600mm | ±1.0% R.D. | ±0.010m/s | ||
Output | Analog output | 1port(Std.) 4-20mA Allowable load resistance 600Ω Max. | ||
Relay output | 1port(Std.) for Totalizing, Warning or Directional output | |||
Digital output | 1port(Std.) USB connection / Inter-communication mode | |||
1port(Option) RS-485 / MODBUS-RTU output | ||||
Input | Analog Input | 1port(Option) 4-20 mA / Passive input | ||
Main unit | Protection Degree | IEC60529 IP65 | ||
Transducer | Applicable Temperature | ‐20 ~ 60℃ | ||
Protection Degree | IEC60529 IP65(Std.) / IEC60529 IP67(Option) | |||
Cable Length | 30m Max. (Applicable cable model : RG-223U) | |||
Data Logging | Over 68,000 lines(exp. more than 1month by 1min interval / Interval selectable) Logged Item; Date, time, Instantaneous flow rate, +Total, -Total, Error code and Event status |
|||
Function | PC Graphical parameter setting 4 key configurable from the console Self-diagnostics Disturbance detection No Echo receiving warning Low flow cut Zero shift |
Span compensation Fixed Analog Output Auto Gain Control Preset Totalize Start Data Retention Echo-wave form monitor Error Status indication |
*1: Site calibration required.
*1 : Space volume of main unit reduced 60% relative to comparable TOKYO KEIKI products.*2 : Power consumption reduction (approx.): -5% at AC100V / -14.8% at AC200V / -10% at DC24V